About UPS systems

Uninterruptible power supplies for server racks and network cabinets, sized to the load and the runtime you need. Sourced to order; send the equipment list and the team will quote a suitable UPS.

An uninterruptible power supply sits between the mains and your equipment and keeps power flowing from its battery when the mains fails or dips. For a server it does two things: it rides through the short interruptions that would otherwise reboot the machine, and in a longer outage it gives the server minutes to shut down cleanly before the battery runs out. Most models can signal the server to start that shutdown automatically.

This page explains the choices. UPS systems are sourced to order, sized to the equipment they will protect and the runtime you need, for server rooms, comms rooms and network cabinets across Qatar.

Types
Line-interactive, online double-conversion
Formats
Rack-mount 1U to 3U, tower
Sizing
By load in watts and runtime in minutes
Availability
Sourced to order

UPS types

TypeHow it worksTypical use
Standby (offline)Passes mains through and switches to battery when it failsDesktops, a single small switch
Line-interactiveCorrects under- and over-voltage without using the battery; switches to battery on failureNetwork cabinets, small servers, branch offices
Online double-conversionRuns the load from the inverter at all times, so output is clean regardless of the mainsProduction servers, storage, anything sensitive to supply quality

Online units cost more and use a little more electricity, but the equipment never sees a transfer and is isolated from the dips, spikes and frequency changes that occur on a busy supply.

Sizing a UPS

  • Load. Add the real power draw of everything the UPS will feed, in watts. The ratings on server power supplies are maximums; actual draw is usually well below. Size the UPS so that load is no more than about 70 to 80 percent of its watt rating.
  • VA and watts. UPS units are sold by VA with a lower watt rating. The watt figure is the one to size against.
  • Runtime. Decide what the battery is for: a few minutes to shut down, or long enough to ride out a typical outage. Longer runtimes mean a bigger UPS or external battery packs.
  • Outlets. Server supplies use IEC C13 leads, and larger units C19. Count what you need, and remember a second UPS or a direct feed for the second power supply.
  • Management. A network card lets the UPS report status and trigger shutdowns across the network, rather than through one USB cable to one server.
  • Format. Rack-mount units take 1U to 3U; towers stand beside the cabinet. Batteries are heavy, so a rack UPS goes at the bottom.

Sourcing a UPS through ServerDove

Send the requirement by WhatsApp on +974 5521 2108, email sales@serverdove.com or use the contact page. List the equipment to be protected, the runtime you want and the cabinet it will go in, and the team will propose a unit and quote it with the PDUs to distribute its output. UPS systems can be installed and connected as part of a rack build with a cabinet and server power supplies.