Server Racks & Cabinets

About server racks and cabinets

New floor-standing server cabinets and wall-mount network cabinets from APSYS and StarTech, from 6U to 47U, in 600 and 800 mm widths. Held in Doha for delivery across Qatar.

ServerDove stocks enclosed 19-inch cabinets for servers and network equipment: new floor-standing APSYS cabinets from 15U to 47U in 600 and 800 mm widths, a 6U APSYS wall-mount cabinet for small installations, and a refurbished StarTech 24U cabinet. All take standard EIA 19-inch rack-mount equipment on front and rear mounting rails.

It is for IT teams, integrators and businesses in Qatar fitting out a server room, a comms room or a network closet, or replacing an open frame with a lockable enclosure. New APSYS cabinets come from the manufacturer's Qatar distributor.

Heights
6U wall mount, 15U to 47U floor standing
Footprints
600 x 450 to 800 x 1000 mm
Standard
EIA 19-inch
Condition
APSYS new, StarTech refurbished

Cabinets in the range

ModelHeightWidth x depthDoors and load
APSYS APWM-64066U wall mount600 x 450 mmGlass front, steel rear; 60 kg static
APSYS APFS-811515U800 x 1000 mmFloor standing, takes full-depth servers
APSYS APFS-681818U600 x 800 mmMesh front, double perforated rear; 800 kg on feet
StarTech RK2433BKM24UStandard 19-inch, enclosedFront and rear access, adjustable rails
APSYS APFS-884242U800 x 800 mmMesh front, double perforated rear; 800 kg on feet
APSYS APFS-814747U800 x 1000 mmMesh front, double perforated rear; 800 kg on feet

APSYS floor-standing cabinets are SPCC cold-rolled steel with a powder-coated finish. Other heights, depths and door styles in the APSYS range can be sourced to order.

Choosing a cabinet

  • Height. Count the rack units of everything going in, including a UPS, PDUs, patch panels and blanking space, and leave room to grow. One U is 44.45 mm.
  • Depth. Rack servers are around 700 to 800 mm deep and need room behind them for power leads and cables, so they want a 1000 mm cabinet. Switches, patch panels and routers fit 600 or 800 mm.
  • Width. 600 mm takes the equipment. 800 mm adds space beside the rails for vertical PDUs and cable bundles, which makes a dense rack much tidier.
  • Doors. Mesh and perforated doors let cooling air through and suit servers. Glass doors suit a network closet where the kit runs cool and you want to see the lights.
  • Floor and access. A full cabinet is heavy; check the floor loading and the route in, including door widths and lifts. Allow space to open front and rear doors fully.

Buying a rack from ServerDove

Cabinets are held in Doha for delivery across Qatar and are covered by the ServerDove warranty. Mounting hardware for the servers is in rails and accessories, and power in Power & UPS. The team can deliver, assemble and position the cabinet and rack the equipment as a service; for a size not listed, send the requirement by WhatsApp on +974 5521 2108, email sales@serverdove.com or use the contact page.