Norden SC–LC Single-Mode Duplex Fibre Patch Cord 3m
Price includes warranty
Nordan
مواصفات المنتج
| Type | Fibre optic patch cord |
| Connector A | SC/PC |
| Connector B | LC/PC |
| Configuration | Duplex |
| Fibre Mode | Single-mode |
| Core/Cladding | 9/125µm |
New
Norden SC to LC single-mode duplex fibre patch cord, 3 m, SKU FIB-NORDEN-SCLC-SM-3M, for joining SC panels to LC transceiver ports.
This is a 3 m duplex fibre patch cord from Norden, SKU FIB-NORDEN-SCLC-SM-3M, terminated SC/PC at one end and LC/PC at the other on 9/125µm single-mode (OS2) fibre. It is a conversion lead: it joins a patch panel, wall box or older media converter fitted with the larger SC connector to a switch, server NIC or storage port that takes an LC duplex transceiver. Two fibres carry transmit and receive separately, matching the paired ports on SFP and SFP+ single-mode optics. Network engineers and cabling installers in Qatar buy it to patch mixed SC and LC links in comms rooms and data centres without fitting a hybrid adapter, keeping the link to one patch lead. The 3 m length suits patching between adjacent racks or from a panel to equipment a few units away without heavy slack. We keep it in Doha alongside the refurbished switches, servers and single-mode transceivers it is usually patched to.
FIB-NORDEN-SCLC-SM-3MSpecification
Single-mode 9/125µm fibre is the type used by long-reach optics such as LX and LR modules. It will not give a reliable link with multimode SR optics, which expect 50/125µm or 62.5/125µm fibre, so both transceivers on the link must be single-mode types. Both ends are PC polished, so the cord mates with PC (blue) ports and adapters.
Do not mate either end with an APC (green) connector or adapter. APC end faces are polished at an 8 degree angle and do not meet a PC face cleanly, which causes loss and can damage both end faces. The yellow jacket follows the usual single-mode colour convention, so the cord stands out from orange or aqua multimode leads in a rack with mixed cabling.
Installation
Remove the dust caps only when ready to connect, and inspect or clean both end faces with a fibre cleaning tool before mating, since dust on a single-mode core is a common cause of high loss. Push each connector in until it seats: the SC end is a push-pull connector and the LC end locks with its latch. If the link does not come up, check polarity: the transmit fibre at one end must arrive at the receive port at the other, and the LC duplex clip can usually be opened to swap the two fibres. Route the cord without tight bends, and keep it clear of rack doors and over-tightened cable ties that can crush the jacket. Keep the dust caps and refit them whenever the cord is unplugged or moved.
Part numbers and identification
Condition & testing
- Tested in a compatible system
- Verified against the listed part number and specification
- Fully working; minor cosmetic marks are possible on refurbished units.
- 6-month warranty on every unit we sell, with installation and support across Qatar.
What ships with this part
Images are for illustration. The unit supplied is the one described in the specification and may differ cosmetically.
Our team in Doha answers specification and compatibility questions during working hours.
Ask on WhatsApp sales@serverdove.comWhat is an SC to LC single-mode patch cord used for?
It links a port or panel that uses SC connectors to one that uses LC connectors on a single-mode fibre run. A typical case is patching from an SC-terminated fibre panel to a switch or network card fitted with an LC duplex single-mode transceiver. It saves fitting a hybrid adapter and keeps the link to one patch lead.
Can this cable be used with multimode transceivers?
No. The cord uses 9/125µm single-mode fibre, which is meant for single-mode optics such as LX and LR type modules. Multimode transceivers, usually SR type, expect 50/125µm or 62.5/125µm fibre. Mixing single-mode cable with multimode optics produces high loss or no link, so match the cable to the transceiver type on both ends.
Will it connect to an SFP or SFP+ module?
SFP and SFP+ optical modules generally have an LC duplex receptacle, so the LC end of this cord fits them physically. The module must be a single-mode type for the link to work, and the far end must present an SC/PC single-mode interface. Check the transceiver datasheet for its fibre type and connector before ordering.
What is the difference between PC and APC connectors?
PC connectors have a flat, slightly domed end face and usually blue housings on single-mode. APC connectors are polished at an 8 degree angle and usually green. The two should not be mated with each other, as the mismatch causes loss and can damage end faces. Both ends of this cord are PC, so use it with PC ports and adapters.
Does duplex mean the cable has two fibres?
Yes. A duplex cord contains two fibres so one can transmit and the other receive, which is how most optical Ethernet and Fibre Channel transceivers work. If a link does not come up after patching, polarity is worth checking: the transmit fibre at one end must arrive at the receive port at the other, and LC duplex clips can usually be swapped to correct this.
Why is the cable jacket yellow?
Yellow is the common colour convention for single-mode fibre jackets, while multimode cables are typically orange, aqua or similar. The colour lets technicians identify single-mode leads quickly in a rack with mixed cabling, reducing the chance of patching the wrong fibre type into an optical port.
What does refurbished mean at ServerDove?
Off-lease or decommissioned enterprise hardware that we clean, test and reset in Doha. Every unit goes through POST, burn-in, memory and drive checks and a power-supply check, with firmware and BIOS returned to defaults and drives securely erased.
Can I ask about the exact unit before I buy?
Yes. Message us the SKU on WhatsApp and we will confirm the condition and configuration of the unit in stock, with photos if you want them.
How fast is delivery in Qatar?
Orders ship from Doha and arrive within one working day anywhere in Qatar. Delivery is free on orders over QAR 300.
Can I collect in person?
Yes, from Nuaija Office 7, Doha, usually within 24 hours of ordering. Choose pick-up at checkout and we will message you when it is ready.
What warranty is included?
A 6-month hardware warranty from the delivery date, covering the unit as supplied. If a part fails we repair or replace it. Full terms are on the warranty page.
What is your return policy?
If the unit arrives faulty or not as described, tell us and we will collect it and replace or refund it. Full terms are on the Refund Policy page.
Which payment methods do you accept?
Visa, Mastercard and American Express online. Bank transfer is available for company orders; contact us for details.
Is the price shown the final price?
Yes. The price shown is what you pay; nothing is added at checkout, and every order ships with an invoice in your name or your company's name.
Why buy refurbished
Enterprise hardware, tested in Doha, at a fraction of the price of new
Every unit we sell has already proven itself in a data centre. We test it again, grade it, and back it with a warranty before it leaves our stock.
Tested before it ships
POST, burn-in, memory and power-supply checks on every unit. Anything that fails is repaired or pulled from stock, not sold.
Same performance, lower cost
A Xeon runs the same workloads whether it is new or two years old. Spend the difference on more CPUs, memory or storage.
In stock, not on order
New enterprise hardware can take weeks or months to arrive. Ours is on the shelf in Doha and delivered across Qatar within a day.
Warranty and local support
Every unit is covered. Installation, configuration and hardware support are handled by our own team in Qatar, not a call centre abroad.
