Opticomm LC–LC OM4 Duplex Multimode Fibre Patch Cable 3m
Price includes warranty
ServerDove
مواصفات المنتج
| Type | Duplex multimode fibre patch cable |
| Length | 3 m |
| Connectors | LC to LC, duplex |
| Connector Polish | UPC |
| Fibre Type | OM4 multimode |
| Core / Cladding | 50/125µm |
Refurbished · Tested
Opticomm 3 m LC to LC OM4 duplex multimode fibre patch cable for connecting 850 nm short-reach transceivers in racks.
This is a 3 m duplex multimode fibre patch cable from Opticomm, SKU FIB-OPTICOMM-LCLC-OM4-3M. It is terminated LC/UPC at both ends on 50/125µm OM4 fibre, with an aqua 3.0 mm PVC jacket. It is the short lead used inside a rack or between adjacent cabinets. It joins multimode SFP, SFP+ and SFP28 transceivers on switches, servers, storage arrays and Fibre Channel HBAs, either to each other or to a patch panel. OM4 is the laser-optimised multimode grade for 850 nm optics, so the same lead serves 10GbE SR, 25GbE SR and short-wave Fibre Channel ports. Three metres covers top-of-rack to server runs and patching across a cabinet without a large service loop. We supply it from Doha alongside refurbished servers, switches and HBAs, so buyers in Qatar can order the optics and the leads that connect them together.
FIB-OPTICOMM-LCLC-OM4-3MSpecification
The loss figures are the labelled values per connection. At 3 m the fibre itself adds almost no attenuation, so the connectors account for nearly all of the lead's share of the optical budget, and 0.3 dB or less leaves most of that budget for panels and the rest of the channel.
| Application | Wavelength | Maximum reach on OM4 |
|---|---|---|
| 10GBASE-SR | 850 nm | 400 m |
| 25GBASE-SR | 850 nm | 100 m |
Installation
Use the lead only with multimode SR or SX transceivers that have an LC duplex port, such as 1000BASE-SX SFP, 10GBASE-SR SFP+, 25GBASE-SR SFP28 and short-wave Fibre Channel optics. It is not suitable for singlemode LR optics, which need 9/125µm OS2 cable, normally in a yellow jacket.
Inspect and clean both end faces before mating, and never mate the UPC connectors with green APC connectors, as the mismatched end faces cause high loss and can damage the ferrules. If a link stays down after patching, check polarity: transmit at one end must reach receive at the other, which on most duplex clips can be corrected by swapping the two connectors. Route the lead without tight bends or crushing ties, and do not look into a connector attached to live optics. PVC suits patching inside racks and equipment rooms; where a space requires low smoke zero halogen or plenum-rated cable, follow the local requirement.
Part numbers and identification
Condition & testing
- Tested in a compatible system
- Verified against the listed part number and specification
- Fully working; minor cosmetic marks are possible on refurbished units.
- 6-month warranty on every unit we sell, with installation and support across Qatar.
What ships with this part
Images are for illustration. The unit supplied is the one described in the specification and may differ cosmetically.
Our team in Doha answers specification and compatibility questions during working hours.
Ask on WhatsApp sales@serverdove.comWhich transceivers does an LC OM4 duplex cable work with?
It is used with multimode short-reach optics that have an LC duplex port and operate at 850 nm. Examples are 1000BASE-SX SFP, 10GBASE-SR SFP+ and 25GBASE-SR SFP28 modules, plus short-wave Fibre Channel optics on HBAs and SAN switches. Check that the transceiver at each end is a multimode SR or SX type rather than an LR or other singlemode part.
Can I use this cable with singlemode LR transceivers?
No. Singlemode optics such as 10GBASE-LR are designed for 9/125µm OS2 fibre. This cable uses 50/125µm multimode fibre, and pairing it with singlemode transceivers is not a supported configuration. Singlemode links need a singlemode patch cable, normally with a yellow jacket, with the correct connector polish.
What is the difference between OM3 and OM4?
Both are 50/125µm laser-optimised multimode fibre, use aqua jackets and take the same connectors. OM4 has higher effective modal bandwidth at 850 nm, so it supports longer runs at the same speed. For example, 10GBASE-SR reaches 300 m on OM3 and 400 m on OM4. On a 3 m patch lead the difference has no practical effect on the link.
Is this LC/UPC or LC/APC?
Both ends are LC with a UPC polish, which is the norm for multimode transceivers and panels. APC connectors have an angled end face and are usually green. They should not be mated with UPC connectors, because the mismatched end faces cause high loss and can damage the ferrules.
What does duplex mean on a fibre patch cable?
A duplex cable has two fibres with two connectors at each end, normally clipped together. One fibre carries transmit and the other receive, which matches the two-port LC receptacle on SFP-family transceivers. If a link stays down after patching, check that transmit at one end reaches receive at the other.
What jacket does this cable have?
The jacket is PVC with a 3.0 mm outer diameter, in aqua. PVC is common for patching inside racks and equipment rooms. If a site requires low smoke zero halogen or plenum-rated cable for a particular space, check the local requirement before installing PVC there.
What are the insertion loss and return loss figures?
The cable is labelled with insertion loss of 0.3 dB or less and return loss of 20 dB or greater. Low insertion loss matters most when a link passes through several connections, such as patch panels at each end. The patch leads then use only a small share of the transceiver's optical budget.
What does refurbished mean at ServerDove?
Off-lease or decommissioned enterprise hardware that we clean, test and reset in Doha. Every unit goes through POST, burn-in, memory and drive checks and a power-supply check, with firmware and BIOS returned to defaults and drives securely erased.
Can I ask about the exact unit before I buy?
Yes. Message us the SKU on WhatsApp and we will confirm the condition and configuration of the unit in stock, with photos if you want them.
How fast is delivery in Qatar?
Orders ship from Doha and arrive within one working day anywhere in Qatar. Delivery is free on orders over QAR 300.
Can I collect in person?
Yes, from Nuaija Office 7, Doha, usually within 24 hours of ordering. Choose pick-up at checkout and we will message you when it is ready.
What warranty is included?
A 6-month hardware warranty from the delivery date, covering the unit as supplied. If a part fails we repair or replace it. Full terms are on the warranty page.
What is your return policy?
If the unit arrives faulty or not as described, tell us and we will collect it and replace or refund it. Full terms are on the Refund Policy page.
Which payment methods do you accept?
Visa, Mastercard and American Express online. Bank transfer is available for company orders; contact us for details.
Is the price shown the final price?
Yes. The price shown is what you pay; nothing is added at checkout, and every order ships with an invoice in your name or your company's name.
Why buy refurbished
Enterprise hardware, tested in Doha, at a fraction of the price of new
Every unit we sell has already proven itself in a data centre. We test it again, grade it, and back it with a warranty before it leaves our stock.
Tested before it ships
POST, burn-in, memory and power-supply checks on every unit. Anything that fails is repaired or pulled from stock, not sold.
Same performance, lower cost
A Xeon runs the same workloads whether it is new or two years old. Spend the difference on more CPUs, memory or storage.
In stock, not on order
New enterprise hardware can take weeks or months to arrive. Ours is on the shelf in Doha and delivered across Qatar within a day.
Warranty and local support
Every unit is covered. Installation, configuration and hardware support are handled by our own team in Qatar, not a call centre abroad.